Location -> Products -> Temperature -> Thermocouple and Thermal Resistance -> Thermocouple(Thermal Resistance) For Power Station

Type:thermocouple (thermal resistance) mounted on boiler wall
Illustrate:Application It is used to measure surface temperature of boiler wall tube wall or other cylinders.
Thermocouple (Thermal Resistance) Mounted on Boiler Wall
It is used to measure surface temperature of boiler wall tube wall or other cylinders.
Main Technical Parameters
Accuracy Class: I、Ⅱ
Nominal Pressure: Normal Pressure
Bending Radius: R≥5D
Type & Specification
Type | Graduation | Measuring Range °C |
Nominal Pressure |
Specification | |
L L1 | |||||
WRNK-191M WRNK2-191M |
K | 0~800 |
Insulation Type |
1000 2000 3000 4000 5000 6000 8000 10000 15000 20000 25000 |
1000 2000 3000 4000 5000 6000 8000 10000 15000 20000 25000 |
WREK-191M WREK2-191M |
E | 0~600 | |||
WRNK-192M WRNK2-192M |
K | 0~800 | Shell-connecting Type | ||
WREK-192M WREK2-192M |
E | 0~600 |
- Class-I thermocouple shall be ordered according to agreements.
- Protection tube material is 1Cr18Ni9Ti, and we also produce the tube of other material.
Mounting Method:
It is directly welded on boiler wall.
M8 Screw Fastening

PLS indicate size of R in type selection. ( i.e. diameter of tube wall or boiler wall
Last:thermocouple (thermal Resistanc.. Next:thermocouple mounted on boiler ..