Location -> Products -> Analyzer Instrument -> Lab Instrument -> Lab pH/ORP Meter

Type:CX-LPH--1608A laboratory pH meter
Illustrate:It can be widely used for continuous monitoring of PH values of the solutions in thermal power plants, chemical fertilizer, alloy, environmental protection, pharmaceutical, biochemical, foodstuff, running water, etc.
CX-LPH-1608A Laboratory PH Meter
Brief Introduction1.CX-LPH-1608Ais a PH meter with the most powerful functions and the most convenient operation on the market.
2.In the aspects of the intelligence, the measuring property, the usage environment as well as the external structure, great improvement has been made, so the accuracy of the instruments is very high.
Main Features
1.Double-row nixie tubes display PH value/mV value and temperature respectively.
2.Computer-based: It adopts high-performance CPU chip, high-precision AD conversion technology and SMT technology to complete the multi-parameter measurement, temperature compensation and instrument self-checking, with high precision and good repeatability.
3.Reliability: Single board structure, touch button, no switch knob
4.25°C Conversion: Nernst electrode slope temperature compensation, pure water and ultra-pure water with addition of ammonia converted at 25°C.
5.Standard liquid temperature auto-conversion: It pre-stores the temperature curve of the standard liquid; in the calibration, it can convert pH value of the standard liquid automatically at the set temperature.
6.Auto-determination of error calibration: If the user wrongly uses the standard buffer solution in the calibration, the instrument will prompt automatically.
7.Network function: RS232 bi-directional communication, equipped with a printer or TLab8.0 communications and data processing software
Main Parameters
Display | The double-row Nixie tube shows PH value/mV value and the temperature respectively. |
Measuring range | 0~14.00pH, -l999~ +1999mV, 0~99.9°C |
Resolution | 0.001 PH/0.01PH, 0.1mV, 0.1°C |
Accuracy | ±0 005pH, ±0 2mV, ±0 3°C |
Temperature compensation range | automatic: 0~99.9°C, manual: 0~99.9°C |
Temperature compensation | Nernst electrode slope temperature compensation, pure water and ultra-pure water with addition of ammonia converted at 25°C. |
Input impedance | > 1012Ω |
Communication interface | RS232 bi-directional communication |
Output | 0~1400mV |
Power supply | AC220V ± 22V, 50Hz ± 1Hz, external power supply |
Working conditions | ambient temperature: 0-60°C; relative humidity: ≤90 |
Power-down memory | > 5 years |
Calibration mode | One-point calibration, two-point calibration |
Last:CX-LPH-1602 lab ph meter Next:CX-LPH-1608 laboratory pH meter