Location -> Products -> Analyzer Instrument -> On-line Instrument -> Industry Dissolved Oxygen Analyzer

Type:CX-IDO-1301 industrial dissolved oxygen meter
Illustrate:This instrument is designed for monitoring the oxygen content in the boiler feed water, condensate water and sewage
CX-IDO-1301 Industrial Dissolved Oxygen Meter
Brief Introduction1.It is a kind of high-intelligence in-line meter and used for continuous on-line monitoring
2.It can be equipped with CX-IDO-120F Polarographic Electrode and can automatically switch from ppb level to ppm level of wide-range measurement..
Main Features
1.It can be easily operated.
2.Simple menu structure and text-type man-instrument interaction: Compared with traditional instruments,
3.Adopts classified menu structure, which is similar to that of a computer, it is clearer and more convenient.
4.It can be operated according to the prompts on the screen without the guidance of an operation manual.
5.Multi-parameter display: The oxygen concentration value, input current (or output current), temperature values,
time and status can be displayed on the screen at the same time.
6.Six sub-displays can display such information as the input or output current,temperature, status, week, year, day, hour, minute and second
7.Adapt to different users’ habits and toconform with different reference times set by the users.
Main Parameters
Measuring range and error |
0~100.0ug/L; 0~20.00 mg/L (automatic switching); 0~60% Resolution: 0.1ug/L; 0.01 mg/L; 0.1C |
Resolution | 0.1ug/L; 0.01 mg/L; 0.1C |
Intrinsic error of the whole instrument | ug/L: ±l.0%FS; mg/L: ±0.5%FS, temperature: ±0.5C |
Repeatability | ±0.5%FS |
Stability | ±1.0%FS |
Automatic temperature compensation range | 0~60C, with 25C as the reference temperature |
Response time | <60s (98% and 25C of the final value) 37C: 98% of the final value < 20 s |
Clock accuracy | ±1 minute/month |
Output current error | ≤±l.0%FS |
Isolated output | 0-10mA (load resistance <15KΩ); 4-20mA (load resistance <750Ω) |
Communication interface | RS485 or 232(optional) |
Data storage capacity | l month (1 point/5 minutes) |
Time of saving data | 10 years |
Alarm relay | AC 220V, 3A |
Power supply | 220V±10% 50±1HZ |
Overall dimension |
Secondary meter: 146 (length) x 146 (width) x 108 (depth) mm; Dimension of the hole: 138 x 138mm |
Working conditions | ambient temperature: 0-60C; relative humidity <85% |
The connection tubes for inlet and outlet water | Φ8, Φ10 and Φl2 |