Type:CX-IDO-1301 industrial dissolved oxygen meter

Illustrate:This instrument is designed for monitoring the oxygen content in the boiler feed water, condensate water and sewage

CX-IDO-1301 Industrial Dissolved Oxygen Meter

Brief Introduction
1.It is a kind of high-intelligence in-line meter and used for continuous on-line monitoring
2.It can be equipped with CX-IDO-120F Polarographic Electrode and can automatically switch from ppb level to ppm level of wide-range measurement.. 

Main Features
1.It can be easily operated.
2.Simple menu structure and text-type man-instrument interaction: Compared with traditional instruments,
3.Adopts classified menu structure, which is similar to that of a computer, it is clearer and more convenient.
4.It can be operated according to the prompts on the screen without the guidance of an operation manual.
5.Multi-parameter display: The oxygen concentration value, input current (or output current), temperature values,
time and status can be displayed on the screen at the same time.
6.Six sub-displays can display such information as the input or output current,temperature, status, week, year, day, hour, minute and second
7.Adapt to different users’ habits and toconform with different reference times set by the users.
 
Main Parameters

Measuring range and error 0~100.0ug/L; 0~20.00 mg/L (automatic switching); 0~60%
Resolution: 0.1ug/L; 0.01 mg/L; 0.1C
Resolution 0.1ug/L; 0.01 mg/L; 0.1C
Intrinsic error of the whole instrument ug/L: ±l.0%FS; mg/L: ±0.5%FS, temperature: ±0.5C
Repeatability ±0.5%FS
Stability ±1.0%FS
Automatic temperature compensation range  0~60C, with 25C as the reference temperature
Response time <60s (98% and 25C of the final value) 37C: 98% of the final value < 20 s
Clock accuracy ±1 minute/month
Output current error ≤±l.0%FS
Isolated output 0-10mA (load resistance <15KΩ); 4-20mA (load resistance <750Ω)
Communication interface RS485 or 232(optional)
Data storage capacity l month (1 point/5 minutes)
Time of saving data 10 years
Alarm relay AC 220V, 3A
Power supply 220V±10% 50±1HZ
Overall dimension Secondary meter: 146 (length) x 146 (width) x 108 (depth) mm;
Dimension of the hole: 138 x 138mm
Working conditions ambient temperature: 0-60C; relative humidity <85%
The connection tubes for inlet and outlet water Φ8, Φ10 and Φl2

Last:CX-IDO-1301A industrial dissolv.. Next:CX-IDO-1303 industrial dissolve..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
粉粉嫩嫩的18虎白女,国产在线高清伦免费理视频,一本久久a久久精品vr综合,国产线播放免费人成视频播放,国产在线精品91国自产拍免费