Gas Flow Meter Types

 
The gas flow meter is a precision instrument used to measure the cumulative flow of gas in the pipeline. There are three main methods for flow measurement:
 
Positive displacement flow meters, such as diaphragm gas meters, Roots flow meters, etc., can accurately measure and settle the gas by rotating the volumetric volume.
 
A velocity gas flow meter that measures the volume of fuel gas by the gas flow rate.
 
The way of gas measurement by pressure difference.
sales01@cxflowmeter.com
Flowmeter type:
 
Mass flow meter
 
The mass flow meter determines the mass flow through the flow meter.
 
There are two types worth mentioning here:
 
A direct mass flow measurement based on the deflection force of a fluid through a vibrating tube. It is suitable for large flow and single temperament measurement with high measurement accuracy.
The price is more expensive, not suitable for large-diameter pipeline installation.
Thermal mass flow meter MEMS
 
Thermal mass flow meters perform mass flow measurement based on the heat transfer principle of heating elements. It has excellent accuracy and repeatability, and is easy to install. Velocity flow meters
Turbine flow meters Turbine flow meters measure the volume flow of fluid through a freely rotating rotor; each rotation corresponds to a specific volume of fluid. The disadvantage is that it is suitable for the
measurement of clean and dry gas, and the temperature and pressure compensation function must be selected.


coriolis flow meter
 
coriolis meter can measure gas and liquid, it is a flowmeter with the highest measurement accuracy, but the price is high, and it is generally used in enterprises that require very high accuracy.
Ultrasonic flowmeter
 
Adopting the time difference method, using a pair of ultrasonic transducers to alternately (or simultaneously) transmit and receive ultrasonic waves, measure the flow velocity of the fluid by observing its forward
and reverse propagation time in the medium, and then calculate the flow rate by the flow velocity, which is an indirect , Non-contact measuring instrument, high measurement accuracy, wide range, pressure resistance,
corrosion resistance; small size, easy to install. However, the price is higher, and temperature and pressure corrections are required.
Vortex Flowmeter
 
The vortex flowmeter is a new type of flowmeter that measures fluid flow in closed pipelines based on the Karman vortex principle. Because of its good medium adaptability, it can directly measure the volume flow of steam, air,
gas, water, and liquid without temperature and pressure compensation. Equipped with temperature and pressure sensors, it can measure the volume flow and mass flow under standard conditions, which is throttling.
The ideal substitute product of type flowmeter.
Vortex flow meter is the best flowmeter for measuring steam
Differential pressure flow meter
 
The differential pressure flowmeter calculates the flow rate by measuring the pressure drop on the obstacle inserted in the flow channel. Common types of differential pressure flow meters include orifice type, nozzle type, venturi tube type,
and constant velocity tube type.
Orifice flowmeter
 
It is a commonly used differential pressure flow meter in natural gas metering. It measures volume flow, not mass flow. Its limitations include low accuracy for small flow rates. In addition, because it is a volumetric flow meter,
it needs temperature and pressure corrections to achieve mass flow.
 
Averaging tube is a commonly used device for measuring combustion air and differential pressure flow. Due to certain limitations: especially the low flow sensitivity and range cannot meet the measurement requirements.
The measurement depends on the actual speed and pressure, and the flow signal may not be received at low speeds.

If you want to know more, please consult winny: sales01@cxflowmeter.com

 

Last:CIXIFM P Series Micro Gear Flow.. Next:Steam Vortex Flow Meter Working..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
粉粉嫩嫩的18虎白女,国产在线高清伦免费理视频,一本久久a久久精品vr综合,国产线播放免费人成视频播放,国产在线精品91国自产拍免费