Location -> News
News
Compressed air flow meter selection
Email: sales01@cxflowmeter.com
Whatsapp: 008618049841995
Compressed air flow meter selection
Today, a customer asked about the selection of compressed air flow meter. At first, he said he needed a DN200 thermal mass flow meter,
but after analysis by our technicians, we recommended another model
but after analysis by our technicians, we recommended another model
Here are the information parameters he provided:
Medium: compressed air
Working pressure: 0.8Mpa
Maximum flow: 15000m³/h
Range ratio ≥100:1
Accuracy level: ≤1.0
Later, after analysis by our technicians
Recommended Coriolis flow meter for him
The following are the parameters of Coriolis flow meter:
Coriolis mass flow meter DN200
Medium: compressed air
Rated flow 15000 cubic/H
Accuracy: 1%
Installation method: flange connection
Installation size: DN200
With LCD display
Material: 316L
Temperature: -30-150°C
Pressure: 1.6MPa
Output: 4-20 mA +485
Power supply: 24V M20*1.5
Explosion-proof grade: ExdIIBT4
Protection level: IP67
If you are also troubled by the flow meter selection and don’t know how to choose a suitable air flow meter, please consult CIXIFM winny:
Email: sales01@cxflowmeter.com
Whatsapp: 008618049841995
Last:How to choose a Coriolis flow m.. Next:Coriolis mass flow meter for ul..