Type:assembly thermal resistance

Illustrate:It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from -200℃ to 500℃ during various production process.

Assembly thermal resistance

 

Application
It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from -200℃ to 500℃ during various production process.

Feature

Spring thermal sensor with good shock-proof performance
No compensational wire, spare cost.
High measuring accuracy
High mechanical strength, good pressure-resistant performance
imported film resistor with stable & reliable performance

Operation theory

It is based on that temperature change of material results in charge of its resistance.
When resistance value change, the working instrument will display relevant temperature.
 
Main technical parameters

Executive standard
IEC751
IB/T8622-1997
JB/T8623-1997
 
Insulation resistance at normal temperature

The insulation resistance between electrode and protection tube of armored resistance shall be no less than 100M Ω
under condition that environment temperature is 15~35 C, relative humidity is no more than 80%, and testing voltage is D.C.10~100V.
 
Measuring range and tolerance
Model  Graduation Temperature range  Accuracy  Tolerances 
WZP  Pt100  -200-+500 Grade A  ± ( 0.15+0.002) ltl 
Grade B  ± ( 0.30+0.005) ltl 
WZC Cu50   Cu100  -50-+100  ---  ± ( 0.30+0.005) ltl 
 
  Remark: t is absolute value actually tested with thermal sensor.

Type naming method
 

W Temperature instrument 
  R themal resistance
  Thermal element material 
p Pt
C Cu
  Filament
Blank simplex
2 Duplex 
  Mounting &fixing 
1 Without fixing device
2 Threaded connector
3 Movable flange
4 Fixed flange
5 Elbow tube connector
6 Threaded cone connection
7 Straight tube connector
8 Fixed threaded tube connector
9 Movable threaded tube connector
  Junction box
2 Anti-spray type
3 Water-proof type
  Protection tube diameter
0 Φ16 
1 Φ12
  Measuring end
G  Variable cross section
W z p 2 2 3 1 G Model example



Type and specification
 
Thermal element
 

Name Type Graduation Measuring 
range ℃
specification
d L
Simplex Pt
thermal 
resistance
WZP-101 Pt100 -200~500 Φ3
Φ4
Φ5
Φ6
310
360
410
460
510
560
Duplex Pt
thermal
resistance
WZP2-101
 
Wiring method
 